The transformers are housed in a cast aluminium case, vacuum impregnated with epoxy resin and finished in epoxy paint for added protection. High purity alumina ceramic insulators with arcing horns are fitted as standard and an integral static drain to earth provides additional protection against lightning induced EMF’s.
- Wide band 1.5 to 32 MHz
- 1 kW average, 4kW PEP
- All weather solid encapsulated
- Fixed station or transportable antenna arrays
For added EMP proof operation no capacitors are used in the transformer circuit. A wide selection of unbalanced and balanced impedance ratios are available to complement most antenna configurations and enquiries for non-standard arrangements are welcome. No compromise has been made to provide a unit of the highest standard of reliability.
HF10 Dimensional Drawing
Type Designations for HF10 Series and Technical Specification
Balance Impedance (ohm)
|
||||||||
Unbalanced impedance (ohm)
|
50
|
75
|
100
|
200
|
300
|
370
|
450
|
600
|
50
|
HF10-55 | HF10-57 | HF10-510 | HF10-520 | HF10-530 | HF10-537 | HF10-545 | HF10-560 |
75
|
HF10-75 | HF10-77 | HF10-710 | HF10-720 | HF10-730 | HF10-737 | HF10-745 | HF10-760 |
Frequency: | 1.5 – 32 MHz |
Impedance: | See table above |
Power: | 1kW average, 4kW peak |
Insertion loss: | Less than 0.3 dB |
VSWR: | Less than 1.2:1 (2 – 30 MHz), Less than 1.3:1 (1.5 – 32 MHz) |
Balance ratio: | Greater than 26 dB |
Load VSWR: | 2.5:1 max. |
Coaxial connectors: | ‘N’ type (Others on request) |
Balance terminals: | Alumina ceramic M10 thread |
Temperature range: | -40ºC to +55ºC |
Weight: | 5kg gross |
High voltage protection: | Arcing horns and internal static drain (NB No internal capacitors fitted.) |
Configuration: | Cast aluminium case (LM25). Hermetically sealed. Epoxy paint finish. |
Shipping dimensions: | 425 x 300x 150 mm approx. |