VDC Series

  • Wide band operation models for
    • 20Hz – 20KHz
    • 100Hz – 200KHz
    • 50KHz – 10Mhz
    • 1.5 MHz to 32 MHz
  • 1 Watt Average
  • 2 Watts PEP
  • Fully encapsulated

The Minns Baluns VDC Series are designed for precision measurement purposes where 50/600 Ohm transformation is required with low VSWR and high balance ratio.

All the measuring transformers are fully encapsulated within a cast aluminium case to provide a high stability product capable of withstanding the most severe environment.

VDC Dimensional

Type Designations for VDC Series and Technical Specification

Balance Impedance (ohm)
Standard Frequency Ranges
Balanced Terminals
Balance Ratio
VSWR
BNC’
N’
UHF’
20Hz – 20kHz
Ceramic M6
>12dB
1.1 : 1
VDC08A
VDC08B
VDC08C
100Hz – 200kHz
Ceramic M6
>50dB
1.1 : 1
VDC05A
VDC05F
VDC05G
50kHz – 10MHz
Ceramic M6
>40dB
1.1 : 1
VDC06A
VDC06F
VDC06G
1.5MHz – 32MHz
Ceramic M6
>26db
1.1 : 1
VDC02B
VDC02A
VDC02C
Frequency Range See Table Above
Unbalanced Impedance: 50 ohms
Balanced Impedance: 600 ohms
Power Rating; +10dBm
Insertion loss: Less than 0.2 dB
VSWR: See Table Above
Balance ratio: See Table Above
Balance Connection: M6 Insulators
Unbalanced Connection: See Table Above
Temperature range: -20ºC to +55ºC